Kubota P0563 — Fault Code Guide

Official Description: 168 3 Battery Potential / Power Input 1 Open circuit, short circuit or damage of harness Failure of battery - Key switch is ON - Starter switch signal (ECU: V12 terminal) is not activated ECU recognition of battery voltage is 16 V or more one sec or more Output limitation: Approximately 75% of normal condition EGR stop Intake throttle 100% open ON - Faulty starting - Insufficient output - Worsening exhaust gas emissions Key switch turn OFF ―

Recommended Replacement Part: Egt Exhaust Gas Temperature Sensor
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →

Quick Diagnostic Checklist

  1. Inspect Harness & Connectors: Check for loose pins, corrosion, oil contamination, or chafed wires near the EGT exhaust gas temperature sensor.
  2. Verify Supply Voltage & Ground: Test reference voltage (typically 5V or 12V/24V depending on circuit) with a multimeter.
  3. Test or Replace Component: If wiring tests good and code P0563 remains active, replace the EGT exhaust gas temperature sensor and clear logged codes.

Source reference: Codes Défaut KUBOTA.pdf (Page 4)