Kubota P2122 — Fault Code Guide
Official Description: 91 4 Accelerator Pedal Position 1 Ground short circuit or open circuit of sensor or harness - Battery voltage is normal - Sensor supply voltage VCC2 is normal Voltage of accelerator position sensor 1 is 0.3 V or less transient Forced Idle (Accelerator = 0%) ON - Insufficient output Diagnostic counter = zero 3 sec
Recommended Replacement Part: Crankshaft Camshaft Position Sensor
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Quick Diagnostic Checklist
- Inspect Harness & Connectors: Check for loose pins, corrosion, oil contamination, or chafed wires near the crankshaft camshaft position sensor.
- Verify Supply Voltage & Ground: Test reference voltage (typically 5V or 12V/24V depending on circuit) with a multimeter.
- Test or Replace Component: If wiring tests good and code P2122 remains active, replace the crankshaft camshaft position sensor and clear logged codes.