Kubota P3008 — Fault Code Guide
Official Description: 3701 0 Diesel Particulate Filter Status PM accumulation level 5 - Battery voltage is normal PM accumulation more than trigger level Regeneration level = 5 transient Output limitation: Approximately 50% of normal condition To minimize PM emission Engine is not stopped forcibly by ECU However KUBOTA strongly recommends operator to stop engine as soon as possible ON - Insufficient output Key switch turn OFF (Reset by Service tool) ―
Recommended Replacement Part: Pressure Switch
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Quick Diagnostic Checklist
- Inspect Harness & Connectors: Check for loose pins, corrosion, oil contamination, or chafed wires near the pressure switch.
- Verify Supply Voltage & Ground: Test reference voltage (typically 5V or 12V/24V depending on circuit) with a multimeter.
- Test or Replace Component: If wiring tests good and code P3008 remains active, replace the pressure switch and clear logged codes.