Kubota P3018 — Fault Code Guide
Official Description: 523599 0 proprietary All exhaust temp. sensor failure simultaneously - Engine speed is 1400 rpm or more - Quantity of injection is 30 mm3/st or more - Coolant temp. is 65 degC (149 degF) or more: continues longer than 300 sec - Intake air temp. is 0 degC (32 degF) or more - Passed 100 sec after cranking All exhaust temp. sensor failure (sensor low) simultaneously 100 sec or more Output limitation: Approximately 75% of normal condition ON - Diagnostic counter = zero Immediately
Recommended Replacement Part: Replacement Sensor Or Valve
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Quick Diagnostic Checklist
- Inspect Harness & Connectors: Check for loose pins, corrosion, oil contamination, or chafed wires near the replacement sensor or valve.
- Verify Supply Voltage & Ground: Test reference voltage (typically 5V or 12V/24V depending on circuit) with a multimeter.
- Test or Replace Component: If wiring tests good and code P3018 remains active, replace the replacement sensor or valve and clear logged codes.