Kubota P3024 — Fault Code Guide
Official Description: 523602 0 proprietary Time interval from the end time to the start time of the regeneration - Battery voltage is normal - Key switch is ON Regeneration time interval within 30 min. occurs three times continuously transient Output limitation: Approximately 50% of normal condition EGR stop ON - Worsening exhaust gas emissions (NOx) Key switch turn OFF (Reset by Service tool) ―
Recommended Replacement Part: Egt Exhaust Gas Temperature Sensor
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Need to get your machine back on the job fast? Check OEM-quality aftermarket stock and pricing:
Shop Kubota Replacement Parts on FridayParts →
Quick Diagnostic Checklist
- Inspect Harness & Connectors: Check for loose pins, corrosion, oil contamination, or chafed wires near the EGT exhaust gas temperature sensor.
- Verify Supply Voltage & Ground: Test reference voltage (typically 5V or 12V/24V depending on circuit) with a multimeter.
- Test or Replace Component: If wiring tests good and code P3024 remains active, replace the EGT exhaust gas temperature sensor and clear logged codes.